MTZ1 06L1 – 630 A – 3P drawout – Micrologic 5.0
- Description
- Size Guide
- More Products
Description
Range | MasterPacT |
---|---|
product name | MasterPact MTZ1 |
Device short name | MTZ1 06 L1 |
Product or component type | Circuit breaker |
Device application | Power distribution protection |
Poles description | 3P |
Control unit | Micrologic 5.0 |
Product compatibility | control unit MicroLogic 2.0 X control unit MicroLogic 5.0 X control unit MicroLogic 6.0 X control unit MicroLogic 7.0 X control unit MicroLogic 2.0 Xi control unit MicroLogic 5.0 Xi control unit MicroLogic 6.0 Xi control unit MicroLogic 7.0 Xi |
[In] rated current | 630 A at 40 °C |
Performance type | L1 150 kA 415 V AC |
[Ue] rated operational voltage | 690 V AC 50/60 Hz |
Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
Selectivity category | Category A |
Control type | Push-button |
Mounting mode | Drawout |
[Icu] rated ultimate short-circuit breaking capacity | 150 kA at 220/415 V AC 50/60 Hz 130 kA at 440 V AC 50/60 Hz 100 kA at 500/525 V AC 50/60 Hz |
---|---|
[Ics] rated service breaking capacity | 150 kA at 220/415 V AC 50/60 Hz 130 kA at 440 V AC 50/60 Hz 100 kA at 500/525 V AC 50/60 Hz |
[Icw] rated short-time withstand current | 10 kA 0.5 s |
[Icm] rated short-circuit making capacity | 330 kA 220/415 V AC at 50/60 Hz 286 kA 440 V AC at 50/60 Hz 220 kA 500/525 V AC at 50/60 Hz 52 kA 660/690 V AC at 50/60 Hz |
Integrated instantaneous protection (DIN in kA peak) | 5.67…6.93 kA |
Sensor rating | 400 A 630 A |
[Ui] rated insulation voltage | 1000 V AC 50/60 Hz |
[Uimp] rated impulse withstand voltage | 12 kV |
Power dissipation in W | 115 W |
Maximum breaking time | 9 ms |
Maximum closing response time | 50 ms |
Mounting support | Rails Base plate |
Upside connection | Front Rear |
Downside connection | Front Rear |
Connection pitch | 70 mm |
Mechanical durability | 12500 cycles with periodic preventive maintenance |
Electrical durability | AC-23A: 3000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-23A: 6000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3 2000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2 3000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
Height | Drawout circuit breaker with chassis: 322 mm Drawout circuit breaker without chassis: 259.5 mm |
Width | Drawout circuit breaker with chassis: 288 mm Drawout circuit breaker without chassis: 236.5 mm |
Depth | Drawout circuit breaker with chassis: 291 mm Drawout circuit breaker without chassis: 207.5 mm |
Product weight | 30 kg |